{"title":"Commercial Refrigeration","description":null,"products":[{"product_id":"r-407a-refrigerant-25-lb","title":"R-407A REFRIGERANT 25 LB","description":"\n\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;color:#152235;line-height:1.7;max-width:1100px;margin:auto;\"\u003e\n\n  \u003c!-- HEADER --\u003e\n  \u003cdiv style=\"background:#080f1e;padding:38px 26px;border-radius:14px;text-align:center;border-bottom:5px solid #087cff;\"\u003e\n    \u003cp style=\"color:#59b6ff;font-size:13px;font-weight:bold;letter-spacing:3px;margin:0 0 12px;\"\u003e\n      GQSBIKE | REFRIGERATION SOLUTIONS\n    \u003c\/p\u003e\n    \u003ch2 style=\"color:#ffffff;font-size:32px;margin:0 0 12px;\"\u003e\n      R-407A REFRIGERANT\n    \u003c\/h2\u003e\n    \u003cp style=\"color:#dceaff;font-size:18px;margin:0;\"\u003e\n      25 LB (11.3 KG) CYLINDER\n    \u003c\/p\u003e\n    \u003cp style=\"color:#a9bfd8;font-size:14px;margin:16px 0 0;\"\u003e\n      Professional Refrigerant for Commercial Cooling \u0026amp; Refrigeration Systems\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- INTRODUCTION --\u003e\n  \u003cdiv style=\"padding:30px 8px;\"\u003e\n    \u003ch2 style=\"color:#075cc5;font-size:25px;\"\u003e\n      Professional R-407A Refrigerant\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      R-407A is a hydrofluorocarbon (HFC)\n      zeotropic refrigerant blend developed for\n      compatible low- and medium-temperature\n      commercial refrigeration applications.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Formulated with R-32, R-125 and R-134a,\n      R-407A offers a lower global warming potential\n      than R-404A and R-507A. It is used in selected\n      refrigeration systems where equipment\n      compatibility has been established.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      GQSBIKE presents the R-407A 25 LB\n      refrigerant cylinder for professional\n      refrigeration servicing and approved\n      retrofit applications. Always verify\n      the actual product label, cylinder contents,\n      system requirements and manufacturer\n      documentation before use.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- PRODUCT HIGHLIGHTS --\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:15px;margin:10px 0 35px;\"\u003e\n\n    \u003cdiv style=\"flex:1 1 190px;background:#f0f6ff;border:1px solid #cfe3ff;border-top:4px solid #087cff;padding:20px;border-radius:10px;\"\u003e\n      \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n        25 LB Cylinder\n      \u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin-bottom:0;\"\u003e\n        Advertised net refrigerant quantity\n        of 25 LB \/ approximately 11.3 KG.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex:1 1 190px;background:#f0f6ff;border:1px solid #cfe3ff;border-top:4px solid #087cff;padding:20px;border-radius:10px;\"\u003e\n      \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n        Lower-GWP HFC Blend\n      \u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin-bottom:0;\"\u003e\n        Lower global warming potential than\n        R-404A for selected refrigeration applications.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex:1 1 190px;background:#f0f6ff;border:1px solid #cfe3ff;border-top:4px solid #087cff;padding:20px;border-radius:10px;\"\u003e\n      \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n        Commercial Refrigeration\n      \u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin-bottom:0;\"\u003e\n        Intended for compatible low- and\n        medium-temperature cooling equipment.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003cdiv style=\"border:1px solid #d9e5f5;border-radius:12px;overflow:hidden;margin-bottom:35px;\"\u003e\n\n    \u003cdiv style=\"background:#080f1e;padding:17px 22px;\"\u003e\n      \u003ch2 style=\"color:#ffffff;font-size:22px;margin:0;\"\u003e\n        Technical Specifications\n      \u003c\/h2\u003e\n    \u003c\/div\u003e\n\n    \u003ctable style=\"border-collapse:collapse;width:100%;font-size:15px;\"\u003e\n      \u003ctbody\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eProduct Name\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            R-407A Refrigerant\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eRefrigerant Family\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            HFC Zeotropic Blend\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eComposition\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            R-32 (20%), R-125 (40%), R-134a (40%)\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eAdvertised Net Weight\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            25 LB \/ Approximately 11.3 KG\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eSafety Classification\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            ASHRAE A1\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eGlobal Warming Potential\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            2107 (IPCC AR4)\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eOzone Depletion Potential\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            0\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eRecommended Lubricant\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            POE (Polyol Ester), per equipment requirements\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;\"\u003e\n            \u003cstrong\u003ePrimary Application\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;\"\u003e\n            Low- and Medium-Temperature Refrigeration\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- APPLICATIONS --\u003e\n  \u003cdiv style=\"background:#f0f6ff;padding:26px;border-left:5px solid #087cff;border-radius:8px;margin-bottom:30px;\"\u003e\n\n    \u003ch2 style=\"color:#075cc5;margin-top:0;\"\u003e\n      Common R-407A Applications\n    \u003c\/h2\u003e\n\n    \u003cul style=\"padding-left:22px;\"\u003e\n      \u003cli\u003eCompatible supermarket refrigeration equipment\u003c\/li\u003e\n      \u003cli\u003eCommercial refrigeration systems\u003c\/li\u003e\n      \u003cli\u003eRefrigerated food display and storage cases\u003c\/li\u003e\n      \u003cli\u003eSelected walk-in coolers and freezers\u003c\/li\u003e\n      \u003cli\u003eCompatible refrigerated transport equipment\u003c\/li\u003e\n      \u003cli\u003eApproved R-404A and R-507A retrofit applications\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cp style=\"font-size:13px;margin-bottom:0;\"\u003e\n      Important: R-407A must only be used in\n      equipment approved for this refrigerant.\n      System compatibility must be assessed by\n      qualified refrigeration professionals.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNOLOGY --\u003e\n  \u003cdiv style=\"border:1px solid #cfe3ff;border-radius:12px;overflow:hidden;margin-bottom:30px;\"\u003e\n\n    \u003cdiv style=\"background:#075cc5;padding:18px 24px;\"\u003e\n      \u003ch2 style=\"color:#ffffff;font-size:21px;margin:0;\"\u003e\n        Advanced R-407A Refrigerant Technology\n      \u003c\/h2\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"padding:24px;background:#ffffff;\"\u003e\n\n      \u003cp\u003e\n        R-407A combines three HFC refrigerants\n        to deliver cooling characteristics suitable\n        for selected commercial refrigeration\n        applications.\n      \u003c\/p\u003e\n\n      \u003cp\u003e\n        With a GWP of 2107 according to IPCC AR4,\n        R-407A has a significantly lower GWP\n        than R-404A. Its performance depends on\n        the specific refrigeration system and\n        operating conditions.\n      \u003c\/p\u003e\n\n      \u003cp style=\"margin-bottom:0;\"\u003e\n        R-407A is a zeotropic blend with\n        temperature glide. Proper refrigerant\n        charging procedures and compatible\n        equipment are required.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- RETROFIT SECTION --\u003e\n  \u003cdiv style=\"background:#f0f6ff;padding:26px;border-left:5px solid #087cff;border-radius:8px;margin-bottom:30px;\"\u003e\n\n    \u003ch2 style=\"color:#075cc5;margin-top:0;\"\u003e\n      R-404A \u0026amp; R-507A Retrofit Considerations\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      R-407A may be considered as a lower-GWP\n      alternative in selected existing R-404A\n      and R-507A refrigeration systems.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Before retrofitting, technicians should\n      check compressor compatibility, system\n      components, seals, expansion devices,\n      lubricant requirements and operating\n      temperatures.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      R-407A must not be mixed with existing\n      refrigerants. The old refrigerant must\n      be properly recovered, and approved\n      retrofit guidance must be followed.\n    \u003c\/p\u003e\n\n    \u003cp style=\"margin-bottom:0;\"\u003e\n      Because R-407A is a zeotropic blend,\n      it must be charged from the liquid phase\n      according to the manufacturer's instructions\n      to maintain the proper refrigerant composition.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- SAFETY INFORMATION --\u003e\n  \u003cdiv style=\"background:#111827;color:#ffffff;padding:28px;border-radius:12px;margin-bottom:30px;\"\u003e\n\n    \u003ch2 style=\"color:#6dbaff;margin-top:0;\"\u003e\n      Safety \u0026amp; Handling Information\n    \u003c\/h2\u003e\n\n    \u003cp style=\"color:#e5e7eb;\"\u003e\n      R-407A is classified as ASHRAE A1,\n      indicating lower toxicity and no flame\n      propagation under standard classification\n      test conditions. As a pressurized refrigerant,\n      it still requires appropriate handling\n      and storage precautions.\n    \u003c\/p\u003e\n\n    \u003cul style=\"color:#e5e7eb;padding-left:22px;\"\u003e\n      \u003cli\u003eUse only in compatible approved refrigeration systems.\u003c\/li\u003e\n      \u003cli\u003eDo not mix R-407A with other refrigerants.\u003c\/li\u003e\n      \u003cli\u003eUse properly rated recovery and service equipment.\u003c\/li\u003e\n      \u003cli\u003eFollow approved liquid-phase charging procedures.\u003c\/li\u003e\n      \u003cli\u003eStore cylinders securely away from excessive heat.\u003c\/li\u003e\n      \u003cli\u003eEnsure suitable ventilation during handling.\u003c\/li\u003e\n      \u003cli\u003ePrevent liquid contact with skin or eyes to avoid frostbite.\u003c\/li\u003e\n      \u003cli\u003eFollow the current Safety Data Sheet (SDS).\u003c\/li\u003e\n      \u003cli\u003eUse qualified refrigeration professionals for servicing.\u003c\/li\u003e\n      \u003cli\u003eNever intentionally vent refrigerant into the atmosphere.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- PURCHASE INFORMATION --\u003e\n  \u003cdiv style=\"background:#eaf3ff;border:1px solid #a8cdfd;padding:22px;border-radius:10px;margin-bottom:30px;\"\u003e\n\n    \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n      Important Purchase Information\n    \u003c\/h3\u003e\n\n    \u003cp style=\"margin-bottom:0;\"\u003e\n      R-407A is a regulated HFC refrigerant.\n      Purchasing, handling, installation, recovery\n      and transportation must comply with all\n      applicable environmental and safety\n      requirements.\n\n      In the United States, EPA Section 608\n      refrigerant certification requirements\n      and HFC phasedown restrictions may apply.\n\n      Confirm purchaser eligibility, cylinder\n      labeling, actual refrigerant net weight\n      and equipment compatibility before sale\n      or professional use.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- GQSBIKE FOOTER --\u003e\n  \u003cdiv style=\"background:#080f1e;padding:28px;text-align:center;border-radius:12px;\"\u003e\n\n    \u003ch2 style=\"color:#ffffff;margin:0 0 8px;\"\u003e\n      GQSBIKE\n    \u003c\/h2\u003e\n\n    \u003cp style=\"color:#53b4ff;font-size:13px;letter-spacing:2px;margin:0 0 12px;\"\u003e\n      AIR CONDITIONING \u0026amp; REFRIGERATION\n    \u003c\/p\u003e\n\n    \u003cp style=\"color:#b8c5d6;font-size:14px;margin:0;\"\u003e\n      Professional Refrigerant Solutions for\n      Commercial Cooling \u0026amp; Refrigeration Systems\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n","brand":"GQSBIKE","offers":[{"title":"Green","offer_id":71583557157117,"sku":null,"price":99.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0836\/8419\/6605\/files\/4077AA.jpg?v=1792185993"},{"product_id":"r-407c-refrigerant-25-lb","title":"R-407C REFRIGERANT 25 LB","description":"\n\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;color:#152235;line-height:1.7;max-width:1100px;margin:auto;\"\u003e\n\n  \u003c!-- HEADER --\u003e\n  \u003cdiv style=\"background:#080f1e;padding:38px 26px;border-radius:14px;text-align:center;border-bottom:5px solid #087cff;\"\u003e\n    \u003cp style=\"color:#59b6ff;font-size:13px;font-weight:bold;letter-spacing:3px;margin:0 0 12px;\"\u003e\n      GQSBIKE | HVAC REFRIGERANTS\n    \u003c\/p\u003e\n    \u003ch2 style=\"color:#ffffff;font-size:32px;margin:0 0 12px;\"\u003e\n      R-407C REFRIGERANT\n    \u003c\/h2\u003e\n    \u003cp style=\"color:#dceaff;font-size:18px;margin:0;\"\u003e\n      25 LB (11.3 KG) CYLINDER\n    \u003c\/p\u003e\n    \u003cp style=\"color:#a9bfd8;font-size:14px;margin:16px 0 0;\"\u003e\n      Professional Refrigerant for Air Conditioning, Heat Pumps \u0026amp; Compatible Cooling Systems\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- INTRODUCTION --\u003e\n  \u003cdiv style=\"padding:30px 8px;\"\u003e\n    \u003ch2 style=\"color:#075cc5;font-size:25px;\"\u003e\n      Professional R-407C Refrigerant\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      R-407C is a hydrofluorocarbon (HFC)\n      zeotropic refrigerant blend designed for\n      compatible residential and commercial\n      air conditioning, heat pump and\n      medium-temperature refrigeration systems.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Composed of R-32, R-125 and R-134a,\n      R-407C provides operating characteristics\n      suitable for selected cooling applications.\n      It has also been used as an alternative\n      to R-22 in properly evaluated retrofit projects.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      GQSBIKE presents the R-407C 25 LB\n      refrigerant cylinder for professional HVAC\n      servicing and approved refrigeration\n      applications. Always verify the cylinder\n      label, equipment compatibility and\n      manufacturer specifications before use.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- PRODUCT HIGHLIGHTS --\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:15px;margin:10px 0 35px;\"\u003e\n\n    \u003cdiv style=\"flex:1 1 190px;background:#f0f6ff;border:1px solid #cfe3ff;border-top:4px solid #087cff;padding:20px;border-radius:10px;\"\u003e\n      \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n        25 LB Cylinder\n      \u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin-bottom:0;\"\u003e\n        Advertised refrigerant quantity of\n        25 LB \/ approximately 11.3 KG.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex:1 1 190px;background:#f0f6ff;border:1px solid #cfe3ff;border-top:4px solid #087cff;padding:20px;border-radius:10px;\"\u003e\n      \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n        HFC Refrigerant\n      \u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin-bottom:0;\"\u003e\n        R-407C combines three HFC components\n        with zero ozone depletion potential.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex:1 1 190px;background:#f0f6ff;border:1px solid #cfe3ff;border-top:4px solid #087cff;padding:20px;border-radius:10px;\"\u003e\n      \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n        HVAC Applications\n      \u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin-bottom:0;\"\u003e\n        Used in compatible air conditioning,\n        heat pump and refrigeration equipment.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003cdiv style=\"border:1px solid #d9e5f5;border-radius:12px;overflow:hidden;margin-bottom:35px;\"\u003e\n\n    \u003cdiv style=\"background:#080f1e;padding:17px 22px;\"\u003e\n      \u003ch2 style=\"color:#ffffff;font-size:22px;margin:0;\"\u003e\n        Technical Specifications\n      \u003c\/h2\u003e\n    \u003c\/div\u003e\n\n    \u003ctable style=\"border-collapse:collapse;width:100%;font-size:15px;\"\u003e\n      \u003ctbody\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eProduct Name\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            R-407C Refrigerant\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eRefrigerant Family\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            HFC Zeotropic Blend\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eComposition\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            R-32 (23%), R-125 (25%), R-134a (52%)\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eAdvertised Net Weight\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            25 LB \/ Approximately 11.3 KG\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eSafety Classification\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            ASHRAE A1\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eGlobal Warming Potential\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            1774 (IPCC AR4)\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eOzone Depletion Potential\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            0\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eTypical Lubricant\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            POE (Polyol Ester), per system requirements\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;\"\u003e\n            \u003cstrong\u003ePrimary Applications\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;\"\u003e\n            Air Conditioning, Heat Pumps \u0026amp; Medium-Temperature Refrigeration\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- APPLICATIONS --\u003e\n  \u003cdiv style=\"background:#f0f6ff;padding:26px;border-left:5px solid #087cff;border-radius:8px;margin-bottom:30px;\"\u003e\n\n    \u003ch2 style=\"color:#075cc5;margin-top:0;\"\u003e\n      Common R-407C Applications\n    \u003c\/h2\u003e\n\n    \u003cul style=\"padding-left:22px;\"\u003e\n      \u003cli\u003eCompatible residential central air conditioning systems\u003c\/li\u003e\n      \u003cli\u003eCommercial air conditioning equipment\u003c\/li\u003e\n      \u003cli\u003eR-407C rated heat pump systems\u003c\/li\u003e\n      \u003cli\u003eSelected ductless air conditioning systems\u003c\/li\u003e\n      \u003cli\u003eMedium-temperature refrigeration applications\u003c\/li\u003e\n      \u003cli\u003eProfessionally evaluated R-22 retrofit projects\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cp style=\"font-size:13px;margin-bottom:0;\"\u003e\n      Important: Refrigerant compatibility must be\n      confirmed using the equipment manufacturer's\n      documentation and approved servicing guidance.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNOLOGY --\u003e\n  \u003cdiv style=\"border:1px solid #cfe3ff;border-radius:12px;overflow:hidden;margin-bottom:30px;\"\u003e\n\n    \u003cdiv style=\"background:#075cc5;padding:18px 24px;\"\u003e\n      \u003ch2 style=\"color:#ffffff;font-size:21px;margin:0;\"\u003e\n        R-407C Refrigerant Technology\n      \u003c\/h2\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"padding:24px;background:#ffffff;\"\u003e\n\n      \u003cp\u003e\n        R-407C is formulated from three HFC refrigerants\n        and offers cooling characteristics that can be\n        suitable for air conditioning and heat pump systems.\n      \u003c\/p\u003e\n\n      \u003cp\u003e\n        With zero ozone depletion potential, R-407C\n        was developed as an alternative for selected\n        applications previously using R-22.\n        However, R-407C remains a high-GWP\n        refrigerant subject to applicable\n        environmental regulations.\n      \u003c\/p\u003e\n\n      \u003cp style=\"margin-bottom:0;\"\u003e\n        Because R-407C is a zeotropic blend,\n        it exhibits temperature glide.\n        Proper liquid-phase charging and the\n        appropriate dew-point and bubble-point\n        pressure-temperature values are important\n        during professional servicing.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- RETROFIT INFORMATION --\u003e\n  \u003cdiv style=\"background:#f0f6ff;padding:26px;border-left:5px solid #087cff;border-radius:8px;margin-bottom:30px;\"\u003e\n\n    \u003ch2 style=\"color:#075cc5;margin-top:0;\"\u003e\n      R-22 Retrofit Considerations\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      R-407C may be considered for selected\n      existing air conditioning and heat pump\n      systems originally designed for R-22,\n      subject to equipment and manufacturer approval.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Before performing a retrofit, qualified\n      technicians must evaluate compressor\n      compatibility, expansion devices,\n      system seals, lubricant requirements\n      and expected operating conditions.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      R-407C is not a direct drop-in replacement\n      for R-22 and must not be mixed with R-22\n      or any other refrigerant.\n    \u003c\/p\u003e\n\n    \u003cp style=\"margin-bottom:0;\"\u003e\n      Existing refrigerant must be recovered\n      using approved equipment, and the converted\n      system must be serviced and labeled according\n      to applicable retrofit procedures.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- SAFETY INFORMATION --\u003e\n  \u003cdiv style=\"background:#111827;color:#ffffff;padding:28px;border-radius:12px;margin-bottom:30px;\"\u003e\n\n    \u003ch2 style=\"color:#6dbaff;margin-top:0;\"\u003e\n      Safety \u0026amp; Handling Information\n    \u003c\/h2\u003e\n\n    \u003cp style=\"color:#e5e7eb;\"\u003e\n      R-407C is classified as ASHRAE A1,\n      indicating lower toxicity and no flame\n      propagation under standard test conditions.\n      It remains a pressurized refrigerant\n      requiring appropriate professional handling.\n    \u003c\/p\u003e\n\n    \u003cul style=\"color:#e5e7eb;padding-left:22px;\"\u003e\n      \u003cli\u003eUse only in compatible, approved HVAC equipment.\u003c\/li\u003e\n      \u003cli\u003eDo not mix R-407C with other refrigerants.\u003c\/li\u003e\n      \u003cli\u003eUse properly rated service and recovery equipment.\u003c\/li\u003e\n      \u003cli\u003eFollow approved liquid-phase charging procedures.\u003c\/li\u003e\n      \u003cli\u003eProtect cylinders from excessive heat and damage.\u003c\/li\u003e\n      \u003cli\u003eEnsure adequate ventilation while handling refrigerant.\u003c\/li\u003e\n      \u003cli\u003eAvoid liquid refrigerant contact to prevent frostbite.\u003c\/li\u003e\n      \u003cli\u003eConsult the current Safety Data Sheet (SDS).\u003c\/li\u003e\n      \u003cli\u003eHave servicing performed by qualified HVAC technicians.\u003c\/li\u003e\n      \u003cli\u003eNever intentionally vent refrigerant into the atmosphere.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- PURCHASE INFORMATION --\u003e\n  \u003cdiv style=\"background:#eaf3ff;border:1px solid #a8cdfd;padding:22px;border-radius:10px;margin-bottom:30px;\"\u003e\n\n    \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n      Important Purchase Information\n    \u003c\/h3\u003e\n\n    \u003cp style=\"margin-bottom:0;\"\u003e\n      R-407C is a regulated HFC refrigerant.\n      Purchasing, handling, servicing, recovery,\n      transport and disposal must comply with\n      applicable safety and environmental laws.\n    \u003c\/p\u003e\n\n    \u003cp style=\"margin-bottom:0;\"\u003e\n      In the United States, EPA Section 608\n      certification requirements and HFC\n      phasedown restrictions may apply.\n      Confirm purchaser eligibility,\n      equipment compatibility, product labeling\n      and actual cylinder contents before sale or use.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- GQSBIKE FOOTER --\u003e\n  \u003cdiv style=\"background:#080f1e;padding:28px;text-align:center;border-radius:12px;\"\u003e\n\n    \u003ch2 style=\"color:#ffffff;margin:0 0 8px;\"\u003e\n      GQSBIKE\n    \u003c\/h2\u003e\n\n    \u003cp style=\"color:#53b4ff;font-size:13px;letter-spacing:2px;margin:0 0 12px;\"\u003e\n      AIR CONDITIONING \u0026amp; REFRIGERATION\n    \u003c\/p\u003e\n\n    \u003cp style=\"color:#b8c5d6;font-size:14px;margin:0;\"\u003e\n      Professional Refrigerant Solutions for\n      Compatible HVAC \u0026amp; Cooling Systems\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n","brand":"GQSBIKE","offers":[{"title":"Orange","offer_id":71583624691965,"sku":null,"price":99.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0836\/8419\/6605\/files\/407C.jpg?v=1792186498"},{"product_id":"r-134a-refrigerant-30-lb","title":"R-134A REFRIGERANT 30 LB","description":"\n\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;color:#152235;line-height:1.7;max-width:1100px;margin:auto;\"\u003e\n\n  \u003c!-- HEADER --\u003e\n  \u003cdiv style=\"background:#080f1e;padding:38px 26px;border-radius:14px;text-align:center;border-bottom:5px solid #087cff;\"\u003e\n    \u003cp style=\"color:#59b6ff;font-size:13px;font-weight:bold;letter-spacing:3px;margin:0 0 12px;\"\u003e\n      GQSBIKE | HVAC \u0026amp; AUTOMOTIVE REFRIGERANTS\n    \u003c\/p\u003e\n    \u003ch2 style=\"color:#ffffff;font-size:32px;margin:0 0 12px;\"\u003e\n      R-134A REFRIGERANT\n    \u003c\/h2\u003e\n    \u003cp style=\"color:#dceaff;font-size:18px;margin:0;\"\u003e\n      30 LB (13.6 KG) CYLINDER\n    \u003c\/p\u003e\n    \u003cp style=\"color:#a9bfd8;font-size:14px;margin:16px 0 0;\"\u003e\n      Professional Refrigerant for Compatible Automotive A\/C \u0026amp; Refrigeration Systems\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- INTRODUCTION --\u003e\n  \u003cdiv style=\"padding:30px 8px;\"\u003e\n    \u003ch2 style=\"color:#075cc5;font-size:25px;\"\u003e\n      Professional R-134A Refrigerant\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      R-134A, also known as 1,1,1,2-tetrafluoroethane,\n      is a single-component hydrofluorocarbon (HFC)\n      refrigerant commonly used in automotive air\n      conditioning and selected refrigeration systems.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      With zero ozone depletion potential and\n      ASHRAE A1 safety classification, R-134A\n      has been widely used in compatible passenger\n      vehicle A\/C systems, commercial refrigeration,\n      and specialized cooling equipment.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      GQSBIKE presents the R-134A 30 LB refrigerant\n      cylinder for professional servicing of equipment\n      specifically designed for R-134A.\n      Always confirm cylinder labeling, net contents,\n      manufacturer documentation, and equipment\n      compatibility before use.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- PRODUCT HIGHLIGHTS --\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:15px;margin:10px 0 35px;\"\u003e\n\n    \u003cdiv style=\"flex:1 1 190px;background:#f0f6ff;border:1px solid #cfe3ff;border-top:4px solid #087cff;padding:20px;border-radius:10px;\"\u003e\n      \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n        30 LB Cylinder\n      \u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin-bottom:0;\"\u003e\n        Advertised net refrigerant quantity\n        of 30 LB \/ approximately 13.6 KG.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex:1 1 190px;background:#f0f6ff;border:1px solid #cfe3ff;border-top:4px solid #087cff;padding:20px;border-radius:10px;\"\u003e\n      \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n        Single-Component HFC\n      \u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin-bottom:0;\"\u003e\n        R-134A refrigerant with zero ozone\n        depletion potential and A1 classification.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex:1 1 190px;background:#f0f6ff;border:1px solid #cfe3ff;border-top:4px solid #087cff;padding:20px;border-radius:10px;\"\u003e\n      \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n        Multiple Applications\n      \u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin-bottom:0;\"\u003e\n        Used in compatible automotive A\/C\n        and refrigeration equipment.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- SPECIFICATIONS --\u003e\n  \u003cdiv style=\"border:1px solid #d9e5f5;border-radius:12px;overflow:hidden;margin-bottom:35px;\"\u003e\n\n    \u003cdiv style=\"background:#080f1e;padding:17px 22px;\"\u003e\n      \u003ch2 style=\"color:#ffffff;font-size:22px;margin:0;\"\u003e\n        Technical Specifications\n      \u003c\/h2\u003e\n    \u003c\/div\u003e\n\n    \u003ctable style=\"border-collapse:collapse;width:100%;font-size:15px;\"\u003e\n      \u003ctbody\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eProduct Name\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            R-134A Refrigerant\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eRefrigerant Family\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            HFC (Hydrofluorocarbon)\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eChemical Name\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            1,1,1,2-Tetrafluoroethane\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eChemical Formula\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            C2H2F4\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eAdvertised Net Weight\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            30 LB \/ Approximately 13.6 KG\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eSafety Classification\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            ASHRAE A1\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eGlobal Warming Potential\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            1430 (IPCC AR4)\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eOzone Depletion Potential\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            0\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eCAS Number\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            811-97-2\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;\"\u003e\n            \u003cstrong\u003eEquipment Compatibility\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;\"\u003e\n            Systems Specifically Approved for R-134A\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- APPLICATIONS --\u003e\n  \u003cdiv style=\"background:#f0f6ff;padding:26px;border-left:5px solid #087cff;border-radius:8px;margin-bottom:30px;\"\u003e\n\n    \u003ch2 style=\"color:#075cc5;margin-top:0;\"\u003e\n      Common R-134A Applications\n    \u003c\/h2\u003e\n\n    \u003cul style=\"padding-left:22px;\"\u003e\n      \u003cli\u003eCompatible automotive air conditioning systems\u003c\/li\u003e\n      \u003cli\u003eExisting passenger vehicles designed for R-134A\u003c\/li\u003e\n      \u003cli\u003eSelected commercial refrigeration equipment\u003c\/li\u003e\n      \u003cli\u003eCompatible refrigeration chillers\u003c\/li\u003e\n      \u003cli\u003eSelected refrigerated transport equipment\u003c\/li\u003e\n      \u003cli\u003eApproved industrial cooling applications\u003c\/li\u003e\n      \u003cli\u003eProfessional servicing of R-134A rated systems\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cp style=\"font-size:13px;margin-bottom:0;\"\u003e\n      Important: Application suitability depends\n      on the equipment manufacturer, operating\n      requirements, and applicable regulations.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNOLOGY --\u003e\n  \u003cdiv style=\"border:1px solid #cfe3ff;border-radius:12px;overflow:hidden;margin-bottom:30px;\"\u003e\n\n    \u003cdiv style=\"background:#075cc5;padding:18px 24px;\"\u003e\n      \u003ch2 style=\"color:#ffffff;font-size:21px;margin:0;\"\u003e\n        R-134A Refrigerant Technology\n      \u003c\/h2\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"padding:24px;background:#ffffff;\"\u003e\n      \u003cp\u003e\n        R-134A became widely used in automotive\n        air conditioning as an alternative to\n        older ozone-depleting refrigerants such\n        as R-12.\n      \u003c\/p\u003e\n\n      \u003cp\u003e\n        As a single-component refrigerant,\n        R-134A does not experience the\n        composition changes associated with\n        zeotropic refrigerant blends.\n      \u003c\/p\u003e\n\n      \u003cp\u003e\n        R-134A has zero ozone depletion potential,\n        but its global warming potential is\n        relatively high. The use of R-134A\n        is increasingly restricted in certain\n        new equipment and vehicle applications.\n      \u003c\/p\u003e\n\n      \u003cp style=\"margin-bottom:0;\"\u003e\n        R-134A must only be used in systems\n        specifically approved for it.\n        It is not a universal substitute for\n        R-1234yf, R-22, or other refrigerants.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- COMPATIBILITY --\u003e\n  \u003cdiv style=\"background:#f0f6ff;padding:26px;border-left:5px solid #087cff;border-radius:8px;margin-bottom:30px;\"\u003e\n\n    \u003ch2 style=\"color:#075cc5;margin-top:0;\"\u003e\n      Equipment Compatibility \u0026amp; Servicing\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      Before servicing, qualified technicians\n      should verify the refrigerant designation\n      on the equipment or vehicle label.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      R-134A systems require appropriate\n      service fittings, refrigerant recovery\n      equipment, approved lubricants, and\n      manufacturer-specified charging procedures.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Automotive R-134A systems commonly use\n      application-specific PAG lubricants,\n      while certain stationary refrigeration\n      systems use POE lubricants. Always\n      follow the equipment manufacturer's\n      instructions.\n    \u003c\/p\u003e\n\n    \u003cp style=\"margin-bottom:0;\"\u003e\n      Never mix R-134A with R-1234yf or\n      other refrigerants. Any refrigerant\n      conversion must follow applicable\n      approved procedures.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- SAFETY --\u003e\n  \u003cdiv style=\"background:#111827;color:#ffffff;padding:28px;border-radius:12px;margin-bottom:30px;\"\u003e\n\n    \u003ch2 style=\"color:#6dbaff;margin-top:0;\"\u003e\n      Safety \u0026amp; Handling Information\n    \u003c\/h2\u003e\n\n    \u003cp style=\"color:#e5e7eb;\"\u003e\n      R-134A is classified as ASHRAE A1,\n      indicating lower toxicity and no flame\n      propagation under standard test\n      conditions. However, it is a liquefied\n      gas under pressure and requires\n      appropriate safety precautions.\n    \u003c\/p\u003e\n\n    \u003cul style=\"color:#e5e7eb;padding-left:22px;\"\u003e\n      \u003cli\u003eUse only in equipment approved for R-134A.\u003c\/li\u003e\n      \u003cli\u003eDo not mix R-134A with other refrigerants.\u003c\/li\u003e\n      \u003cli\u003eUse properly rated recovery and service equipment.\u003c\/li\u003e\n      \u003cli\u003eStore cylinders in a cool, well-ventilated area.\u003c\/li\u003e\n      \u003cli\u003eProtect cylinders from excessive heat and damage.\u003c\/li\u003e\n      \u003cli\u003eAvoid contact with liquid refrigerant to prevent frostbite.\u003c\/li\u003e\n      \u003cli\u003eDo not expose refrigerant to flames or hot surfaces.\u003c\/li\u003e\n      \u003cli\u003eFollow the current Safety Data Sheet (SDS).\u003c\/li\u003e\n      \u003cli\u003eUse qualified technicians for refrigeration servicing.\u003c\/li\u003e\n      \u003cli\u003eNever intentionally vent refrigerant.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- IMPORTANT PURCHASE NOTICE --\u003e\n  \u003cdiv style=\"background:#eaf3ff;border:1px solid #a8cdfd;padding:22px;border-radius:10px;margin-bottom:30px;\"\u003e\n\n    \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n      Important Purchase Information\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      R-134A is a regulated HFC refrigerant.\n      Purchasing, servicing, handling, recovery,\n      transportation and disposal must comply\n      with applicable environmental and safety\n      requirements.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      In the United States, EPA Section 608\n      or Section 609 requirements may apply\n      depending on the intended use.\n      Federal HFC restrictions also affect\n      R-134A use in certain new products\n      and motor vehicle applications.\n    \u003c\/p\u003e\n\n    \u003cp style=\"margin-bottom:0;\"\u003e\n      Confirm purchaser eligibility, equipment\n      compatibility, actual cylinder contents,\n      refrigerant labeling, and applicable\n      regulations before sale or use.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- FOOTER --\u003e\n  \u003cdiv style=\"background:#080f1e;padding:28px;text-align:center;border-radius:12px;\"\u003e\n\n    \u003ch2 style=\"color:#ffffff;margin:0 0 8px;\"\u003e\n      GQSBIKE\n    \u003c\/h2\u003e\n\n    \u003cp style=\"color:#53b4ff;font-size:13px;letter-spacing:2px;margin:0 0 12px;\"\u003e\n      AIR CONDITIONING \u0026amp; REFRIGERATION\n    \u003c\/p\u003e\n\n    \u003cp style=\"color:#b8c5d6;font-size:14px;margin:0;\"\u003e\n      Professional Refrigerant Solutions for\n      Automotive A\/C \u0026amp; Cooling Applications\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n","brand":"GQSBIKE","offers":[{"title":"blue","offer_id":71583849316605,"sku":null,"price":99.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0836\/8419\/6605\/files\/134.jpg?v=1792187033"},{"product_id":"r-404a-refrigerant-24-lb","title":"R-404A REFRIGERANT 24 LB","description":"\n\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;color:#152235;line-height:1.7;max-width:1100px;margin:auto;\"\u003e\n\n  \u003c!-- HEADER --\u003e\n  \u003cdiv style=\"background:#080f1e;padding:38px 26px;border-radius:14px;text-align:center;border-bottom:5px solid #087cff;\"\u003e\n    \u003cp style=\"color:#59b6ff;font-size:13px;font-weight:bold;letter-spacing:3px;margin:0 0 12px;\"\u003e\n      GQSBIKE | REFRIGERATION SOLUTIONS\n    \u003c\/p\u003e\n    \u003ch2 style=\"color:#ffffff;font-size:32px;margin:0 0 12px;\"\u003e\n      R-404A REFRIGERANT\n    \u003c\/h2\u003e\n    \u003cp style=\"color:#dceaff;font-size:18px;margin:0;\"\u003e\n      24 LB (10.9 KG) CYLINDER\n    \u003c\/p\u003e\n    \u003cp style=\"color:#a9bfd8;font-size:14px;margin:16px 0 0;\"\u003e\n      Refrigerant for Compatible Commercial \u0026amp; Transport Refrigeration Systems\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- INTRODUCTION --\u003e\n  \u003cdiv style=\"padding:30px 8px;\"\u003e\n    \u003ch2 style=\"color:#075cc5;font-size:25px;\"\u003e\n      Professional R-404A Refrigerant\n    \u003c\/h2\u003e\n    \u003cp\u003e\n      R-404A is a hydrofluorocarbon (HFC)\n      refrigerant blend historically used in\n      low- and medium-temperature commercial\n      refrigeration applications.\n    \u003c\/p\u003e\n    \u003cp\u003e\n      Composed of R-125, R-143a and R-134a,\n      R-404A was widely adopted in supermarket\n      refrigeration, food storage, refrigerated\n      transport and other commercial cooling systems.\n    \u003c\/p\u003e\n    \u003cp\u003e\n      GQSBIKE presents this 24 LB R-404A cylinder\n      for professional servicing of compatible\n      existing refrigeration equipment, subject\n      to applicable use restrictions.\n    \u003c\/p\u003e\n    \u003cp\u003e\n      Always verify the actual cylinder label,\n      net contents, product documentation and\n      equipment compatibility before use.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- PRODUCT HIGHLIGHTS --\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:15px;margin:10px 0 35px;\"\u003e\n\n    \u003cdiv style=\"flex:1 1 190px;background:#f0f6ff;border:1px solid #cfe3ff;border-top:4px solid #087cff;padding:20px;border-radius:10px;\"\u003e\n      \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n        24 LB Cylinder\n      \u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin-bottom:0;\"\u003e\n        Advertised refrigerant quantity of\n        24 LB \/ approximately 10.9 KG.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex:1 1 190px;background:#f0f6ff;border:1px solid #cfe3ff;border-top:4px solid #087cff;padding:20px;border-radius:10px;\"\u003e\n      \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n        HFC Refrigerant Blend\n      \u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin-bottom:0;\"\u003e\n        Near-azeotropic HFC blend with\n        ASHRAE A1 safety classification.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex:1 1 190px;background:#f0f6ff;border:1px solid #cfe3ff;border-top:4px solid #087cff;padding:20px;border-radius:10px;\"\u003e\n      \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n        Commercial Cooling\n      \u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin-bottom:0;\"\u003e\n        Used in compatible legacy\n        refrigeration and transport systems.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003cdiv style=\"border:1px solid #d9e5f5;border-radius:12px;overflow:hidden;margin-bottom:35px;\"\u003e\n\n    \u003cdiv style=\"background:#080f1e;padding:17px 22px;\"\u003e\n      \u003ch2 style=\"color:#ffffff;font-size:22px;margin:0;\"\u003e\n        Technical Specifications\n      \u003c\/h2\u003e\n    \u003c\/div\u003e\n\n    \u003ctable style=\"border-collapse:collapse;width:100%;font-size:15px;\"\u003e\n      \u003ctbody\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eProduct Name\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            R-404A Refrigerant\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eRefrigerant Family\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            HFC Blend\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eComposition by Mass\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            R-125 (44%), R-143a (52%), R-134a (4%)\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eAdvertised Net Weight\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            24 LB \/ Approximately 10.9 KG\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eSafety Classification\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            ASHRAE A1\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eGlobal Warming Potential\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            3922 (IPCC AR4)\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eOzone Depletion Potential\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            0\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            \u003cstrong\u003eTypical Lubricant\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;border-bottom:1px solid #d9e5f5;\"\u003e\n            POE (Polyol Ester), per equipment requirements\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background:#f0f6ff;\"\u003e\n          \u003ctd style=\"padding:14px;\"\u003e\n            \u003cstrong\u003eCommon Equipment\u003c\/strong\u003e\n          \u003c\/td\u003e\n          \u003ctd style=\"padding:14px;\"\u003e\n            Compatible Existing Commercial \u0026amp;\n            Transport Refrigeration Systems\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- APPLICATIONS --\u003e\n  \u003cdiv style=\"background:#f0f6ff;padding:26px;border-left:5px solid #087cff;border-radius:8px;margin-bottom:30px;\"\u003e\n\n    \u003ch2 style=\"color:#075cc5;margin-top:0;\"\u003e\n      Common R-404A Applications\n    \u003c\/h2\u003e\n\n    \u003cul style=\"padding-left:22px;\"\u003e\n      \u003cli\u003eCompatible supermarket refrigeration systems\u003c\/li\u003e\n      \u003cli\u003eExisting commercial freezers and cold rooms\u003c\/li\u003e\n      \u003cli\u003eSelected refrigerated food display cases\u003c\/li\u003e\n      \u003cli\u003eCompatible refrigerated transport systems\u003c\/li\u003e\n      \u003cli\u003eExisting commercial walk-in coolers and freezers\u003c\/li\u003e\n      \u003cli\u003eSelected food storage and processing refrigeration equipment\u003c\/li\u003e\n      \u003cli\u003eProfessional servicing of R-404A rated equipment\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cp style=\"font-size:13px;margin-bottom:0;\"\u003e\n      Important: These are historical and existing-system\n      applications. Current regulations may restrict\n      R-404A use in new equipment or servicing.\n      Always verify the applicable requirements.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNOLOGY --\u003e\n  \u003cdiv style=\"border:1px solid #cfe3ff;border-radius:12px;overflow:hidden;margin-bottom:30px;\"\u003e\n\n    \u003cdiv style=\"background:#075cc5;padding:18px 24px;\"\u003e\n      \u003ch2 style=\"color:#ffffff;font-size:21px;margin:0;\"\u003e\n        R-404A Refrigerant Technology\n      \u003c\/h2\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"padding:24px;background:#ffffff;\"\u003e\n\n      \u003cp\u003e\n        R-404A is a near-azeotropic HFC blend\n        developed for refrigeration equipment\n        requiring low- and medium-temperature\n        operating characteristics.\n      \u003c\/p\u003e\n\n      \u003cp\u003e\n        R-404A has zero ozone depletion potential\n        and an ASHRAE A1 safety classification.\n        However, its high global warming potential\n        has resulted in significant environmental\n        restrictions and movement toward lower-GWP\n        refrigerant alternatives.\n      \u003c\/p\u003e\n\n      \u003cp\u003e\n        While R-404A remains present in many existing\n        refrigeration installations, equipment\n        owners should assess regulatory compliance\n        and long-term service requirements.\n      \u003c\/p\u003e\n\n      \u003cp style=\"margin-bottom:0;\"\u003e\n        R-404A is not interchangeable with other\n        refrigerants without an appropriate\n        engineering and compatibility evaluation.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- SYSTEM COMPATIBILITY --\u003e\n  \u003cdiv style=\"background:#f0f6ff;padding:26px;border-left:5px solid #087cff;border-radius:8px;margin-bottom:30px;\"\u003e\n\n    \u003ch2 style=\"color:#075cc5;margin-top:0;\"\u003e\n      System Compatibility \u0026amp; Servicing\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      R-404A should only be used in systems\n      approved for this refrigerant and\n      where its use is legally permitted.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Professional technicians must verify\n      system design, compressor compatibility,\n      expansion devices, approved lubricants\n      and manufacturer service requirements.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      As a refrigerant blend, R-404A should\n      be charged using the liquid phase\n      according to the manufacturer's\n      approved instructions.\n    \u003c\/p\u003e\n\n    \u003cp style=\"margin-bottom:0;\"\u003e\n      R-404A must not be mixed with other\n      refrigerants. Existing refrigerant\n      must be properly recovered before any\n      authorized system conversion.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- SAFETY INFORMATION --\u003e\n  \u003cdiv style=\"background:#111827;color:#ffffff;padding:28px;border-radius:12px;margin-bottom:30px;\"\u003e\n\n    \u003ch2 style=\"color:#6dbaff;margin-top:0;\"\u003e\n      Safety \u0026amp; Handling Information\n    \u003c\/h2\u003e\n\n    \u003cp style=\"color:#e5e7eb;\"\u003e\n      R-404A is classified as ASHRAE A1,\n      meaning lower toxicity and no flame\n      propagation under standard classification\n      conditions. It remains a liquefied\n      refrigerant gas under pressure and must\n      be handled appropriately.\n    \u003c\/p\u003e\n\n    \u003cul style=\"color:#e5e7eb;padding-left:22px;\"\u003e\n      \u003cli\u003eUse only in compatible approved refrigeration systems.\u003c\/li\u003e\n      \u003cli\u003eDo not mix R-404A with other refrigerants.\u003c\/li\u003e\n      \u003cli\u003eUse properly rated refrigerant recovery equipment.\u003c\/li\u003e\n      \u003cli\u003eFollow manufacturer-approved charging procedures.\u003c\/li\u003e\n      \u003cli\u003eKeep cylinders secured and away from excessive heat.\u003c\/li\u003e\n      \u003cli\u003eEnsure suitable ventilation in service areas.\u003c\/li\u003e\n      \u003cli\u003eAvoid skin and eye contact with escaping liquid.\u003c\/li\u003e\n      \u003cli\u003eConsult the current Safety Data Sheet (SDS).\u003c\/li\u003e\n      \u003cli\u003eUse qualified refrigeration technicians for servicing.\u003c\/li\u003e\n      \u003cli\u003eNever intentionally vent refrigerant.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- ENVIRONMENTAL \u0026 PURCHASE INFORMATION --\u003e\n  \u003cdiv style=\"background:#eaf3ff;border:1px solid #a8cdfd;padding:22px;border-radius:10px;margin-bottom:30px;\"\u003e\n\n    \u003ch3 style=\"color:#075cc5;margin-top:0;\"\u003e\n      Important Purchase \u0026amp; Environmental Information\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      R-404A is a high-GWP HFC refrigerant\n      subject to environmental restrictions.\n      Its use in certain new refrigeration\n      equipment has been restricted in the\n      United States and other markets.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      U.S. EPA Section 608 refrigerant sales\n      certification and handling requirements\n      may apply. Additional restrictions under\n      the American Innovation and Manufacturing\n      (AIM) Act may affect particular applications.\n    \u003c\/p\u003e\n\n    \u003cp style=\"margin-bottom:0;\"\u003e\n      Buyers must verify their eligibility,\n      product legality for the intended\n      application, equipment compatibility,\n      cylinder contents and current\n      environmental requirements.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- GQSBIKE FOOTER --\u003e\n  \u003cdiv style=\"background:#080f1e;padding:28px;text-align:center;border-radius:12px;\"\u003e\n\n    \u003ch2 style=\"color:#ffffff;margin:0 0 8px;\"\u003e\n      GQSBIKE\n    \u003c\/h2\u003e\n\n    \u003cp style=\"color:#53b4ff;font-size:13px;letter-spacing:2px;margin:0 0 12px;\"\u003e\n      AIR CONDITIONING \u0026amp; REFRIGERATION\n    \u003c\/p\u003e\n\n    \u003cp style=\"color:#b8c5d6;font-size:14px;margin:0;\"\u003e\n      Professional Refrigerant Product Information\n      for Commercial Cooling Applications\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n","brand":"GQSBIKE","offers":[{"title":"Orange","offer_id":71584649183485,"sku":null,"price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0836\/8419\/6605\/files\/40444AA.jpg?v=1792188600"}],"url":"https:\/\/gqsbike.us\/collections\/commercial-refrigeration.oembed","provider":"GQSBIKE","version":"1.0","type":"link"}